Danfoss
131G2346FC-302P75KT6E66HXXGXXXXSXXXXAXBXCXXXXDX
FC-302P75KT6E66HXXGXXXXSXXXXAXBXCXXXXDX
Variable Speed / Frequency Drive (VSD/VFD) / Inverter - Danfoss (VLT FC 300 series (FC302)) - Order code FC-302P75KT6E66HXXGXXXXSXXXXAXBXCXXXXDX - Rated input voltage (3-phase) 525Vac-600Vac - Rated power (normal duty) 90kW / (heavy duty) 75kW / (normal duty) 120HP / (heavy duty) 100HP - Rated output current 131A (525-600Vac; normal duty) - Frequency (output) 0.2-590Hz - Frame size C2 - IP66 / UL type 4X / NEMA 4X - with FC Protocol; N2 Metasys; FLN Apogee; Modbus RTU communication capability - with Integrated Safe Torque Off (STO)
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
Réf.
131G2346
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
131G2346Danfoss - VLT FC 300 series (FC302)
Description
Variable Speed / Frequency Drive (VSD/VFD) / Inverter - Danfoss (VLT FC 300 series (FC302)) - Order code FC-302P75KT6E66HXXGXXXXSXXXXAXBXCXXXXDX - Rated input voltage (3-phase) 525Vac-600Vac - Rated power (normal duty) 90kW / (heavy duty) 75kW / (normal duty) 120HP / (heavy duty) 100HP - Rated output current 131A (525-600Vac; normal duty) - Frequency (output) 0.2-590Hz - Frame size C2 - IP66 / UL type 4X / NEMA 4X - with FC Protocol; N2 Metasys; FLN Apogee; Modbus RTU communication capability - with Integrated Safe Torque Off (STO)
Caractéristiques
Marque principale
Danfoss
Fonction principale
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Nom de la gamme / famille de produits
VLT
Nom de la sous-gamme
FC 300 series (FC302)
Fréquence du réseau
(input) 50-60 Hz
(output) 0.2-590 Hz
(output) 0.2-590 Hz
Fonctions
Integrated Safe Torque Off (STO)
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Tension d'alimentation (Courant Alternatif)
525Vac-600Vac
Type de réseau électrique
3-phase
Courant nominal
131A (525-600Vac; normal duty)
100A (525-600Vac; heavy duty)
100A (525-600Vac; heavy duty)
Puissance active nominale (kW)
(normal duty) 90kW
(heavy duty) 75kW
(heavy duty) 75kW
Puissance nominale (cv)
(normal duty) 120HP
(heavy duty) 100HP
(heavy duty) 100HP
Protocole de communication
FC Protocol
N2 Metasys
FLN Apogee
Modbus RTU
N2 Metasys
FLN Apogee
Modbus RTU
Entrées numériques
2 x digital inputs (PNP/NPN programmable)
2 x digital inputs (PNP programmable as 1kHz pulse inputs)
2 x digital inputs (PNP/NPN; programmable as digital outputs)
2 x digital inputs (PNP programmable as 1kHz pulse inputs)
2 x digital inputs (PNP/NPN; programmable as digital outputs)
Sorties numériques
2 x digital outputs (programmable as 32kHz pulse outputs)
2 x digital output (SPDT Single Pole Double Throw contact type)
2 x digital output (SPDT Single Pole Double Throw contact type)
Entrées analogiques
2 x analog inputs (0-20mA / 4-20mA / 0-10V DC)
Sorties analogiques
1 x analog output (0-20mA / 4-20mA)
Indice de protection
IP66
UL type 4X
NEMA 4X
UL type 4X
NEMA 4X
Affichage
Graphical local control panel (LCP 102)
Consommation en courant
(525-600Vac; normal duty) 131 A
(525-600Vac; heavy duty) 137 A
(525-600Vac; heavy duty) 137 A
Puissance dissipée
1500 W
1800 W
1800 W
Statut du produit chez le fabricant
Commercialized
Conforme aux normes
EN 61800-5-2
IEC 61508 SIL2
IEC 62061
ISO 13849-1 PLd
cULus
CE
SEMI F47
EAC
ABS
RINA
BV
LR
ClassNK
DNV
GL
IEC 61508 SIL2
IEC 62061
ISO 13849-1 PLd
cULus
CE
SEMI F47
EAC
ABS
RINA
BV
LR
ClassNK
DNV
GL
Documents associés
Nom | Dernière mise à jour | Langue |
---|---|---|
Danfoss - VLT - FC 300 - Selection guide.pdf | 29 Nov 2018 | English (US) |