131G4314
Variable Speed / Frequency Drive (VSD/VFD) / Inverter - Danfoss (VLT AQUA FC 202) - Configuration code FC-202PK75T2E21H2XGXXXXSXXXXAXBXCXXXXDX - Rated input voltage (3-Phase) 200Vac-240Vac - Rated power (normal duty) 0.75kW / (normal duty) 1HP / (normal duty) 1.66kVA - Rated output current 4.6A (200-240Vac; normal duty) - Frequency (output) 0-590Hz - Frame size A3 - IP21 / NEMA 1 - with RFI-filter Class A2 (C3) - with FC protocol; Modbus RTU communication capability - with coated PCB (Class 3C2)
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
Réf.
131G4314
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
131G4314Danfoss - VLT AQUA FC 202
Description
Variable Speed / Frequency Drive (VSD/VFD) / Inverter - Danfoss (VLT AQUA FC 202) - Configuration code FC-202PK75T2E21H2XGXXXXSXXXXAXBXCXXXXDX - Rated input voltage (3-Phase) 200Vac-240Vac - Rated power (normal duty) 0.75kW / (normal duty) 1HP / (normal duty) 1.66kVA - Rated output current 4.6A (200-240Vac; normal duty) - Frequency (output) 0-590Hz - Frame size A3 - IP21 / NEMA 1 - with RFI-filter Class A2 (C3) - with FC protocol; Modbus RTU communication capability - with coated PCB (Class 3C2)
Caractéristiques
Marque principale
Danfoss
Fonction principale
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Nom de la gamme / famille de produits
VLT AQUA
Nom de la sous-gamme
FC 202
Fréquence du réseau
(input) 50-60 Hz
(output) 0-590 Hz
(output) 0-590 Hz
Fonctions
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Tension d'alimentation (Courant Alternatif)
200Vac-240Vac
Type de réseau électrique
3-Phase
Courant nominal
4.6A (200-240Vac; normal duty)
Puissance active nominale (kW)
(normal duty) 0.75kW
Puissance nominale (cv)
(normal duty) 1HP
Protocole de communication
FC protocol
Modbus RTU
Modbus RTU
Entrées numériques
1 x digital input (FWD)
1 x digital input (REV)
1 x digital input (External fault)
3 x digital inputs (programmable)
1 x digital input (REV)
1 x digital input (External fault)
3 x digital inputs (programmable)
Sorties numériques
1 x digital output (open collector)
Entrées analogiques
2 x analog inputs (0-20mA / 4-20mA / 0-10V DC)
Sorties analogiques
1 x analog output (0-20mA / 4-20mA / 0-10V DC)
Indice de protection
IP21
NEMA 1
NEMA 1
Tenue chimique
coated PCB (Class 3C2)
Technologie utilisée dans le composant
RFI-filter Class A2 (C3)
Affichage
Graphical local control panel (LCP 102)
Consommation en courant
(525-600Vac; normal duty) 1.7 A
Puissance apparente nominale (S)
(normal duty) 1.66 kVA
Puissance dissipée
54 W
Type d'application
Water distribution and booster pumps
Wastewater Lift stations
Aeration blowers
Irrigation pumps
Wastewater Lift stations
Aeration blowers
Irrigation pumps
Référence produit fabricant
FC-202PK75T2E21H2XGXXXXSXXXXAXBXCXXXXDX
Statut du produit chez le fabricant
Commercialized
Bénéfices du produit
Less panel space
Direct outdoor installation
Long cable capability as standard
Reduce air conditioning investment
Integrated harmonic mitigation
Printed circuit board protection as standard
Easy commissioning
Minimum 10 years’ lifetime
Direct outdoor installation
Long cable capability as standard
Reduce air conditioning investment
Integrated harmonic mitigation
Printed circuit board protection as standard
Easy commissioning
Minimum 10 years’ lifetime
Degré de pollution
2
Documents associés
Nom | Dernière mise à jour | Langue |
---|---|---|
Danfoss - VLT - AQUA drive - FC 202 - Design guide.pdf | 29 Nov 2018 | English (US) |
Danfoss - VLT - AQUA drive - FC 202 - Selection guide.pdf | 29 Nov 2018 | English (US) |