Danfoss
131H7641FC-302P11KT6E20HXXGXXXXSXXXXAXBXCXXXXDX
FC-302P11KT6E20HXXGXXXXSXXXXAXBXCXXXXDX
Variable Speed / Frequency Drive (VSD/VFD) / Inverter chassis - Danfoss (VLT FC 300 series (FC302)) - Order code FC-302P11KT6E20HXXGXXXXSXXXXAXBXCXXXXDX - Rated input voltage (3-phase) 525Vac-600Vac - Rated power (normal duty) 15kW / (heavy duty) 11kW / (normal duty) 20HP / (heavy duty) 15HP - Rated output current 22A (525-600Vac; normal duty) - Frequency (output) 0.2-590Hz - Frame size B3 - IP20 - with FC Protocol; N2 Metasys; FLN Apogee; Modbus RTU communication capability - with Integrated Safe Torque Off (STO)
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
131H7641
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
131H7641Danfoss - VLT FC 300 series (FC302)
Description
Variable Speed / Frequency Drive (VSD/VFD) / Inverter chassis - Danfoss (VLT FC 300 series (FC302)) - Order code FC-302P11KT6E20HXXGXXXXSXXXXAXBXCXXXXDX - Rated input voltage (3-phase) 525Vac-600Vac - Rated power (normal duty) 15kW / (heavy duty) 11kW / (normal duty) 20HP / (heavy duty) 15HP - Rated output current 22A (525-600Vac; normal duty) - Frequency (output) 0.2-590Hz - Frame size B3 - IP20 - with FC Protocol; N2 Metasys; FLN Apogee; Modbus RTU communication capability - with Integrated Safe Torque Off (STO)
Specifications
Primary brand
Danfoss
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
VLT
Sub-range name
FC 300 series (FC302)
Network frequency
(input) 50-60 Hz
(output) 0.2-590 Hz
(output) 0.2-590 Hz
Functions
Integrated Safe Torque Off (STO)
Variable Speed / Frequency Drive (VSD/VFD) / Inverter chassis
Variable Speed / Frequency Drive (VSD/VFD) / Inverter chassis
Supply voltage (AC)
525Vac-600Vac
Type of network
3-phase
Rated current
22A (525-600Vac; normal duty)
18A (525-600Vac; heavy duty)
18A (525-600Vac; heavy duty)
Rated active power (kW)
(normal duty) 15kW
(heavy duty) 11kW
(heavy duty) 11kW
Rated power (HP)
(normal duty) 20HP
(heavy duty) 15HP
(heavy duty) 15HP
Communication protocol
FC Protocol
N2 Metasys
FLN Apogee
Modbus RTU
N2 Metasys
FLN Apogee
Modbus RTU
Digital inputs
2 x digital inputs (PNP/NPN programmable)
2 x digital inputs (PNP programmable as 1kHz pulse inputs)
2 x digital inputs (PNP/NPN; programmable as digital outputs)
2 x digital inputs (PNP programmable as 1kHz pulse inputs)
2 x digital inputs (PNP/NPN; programmable as digital outputs)
Digital outputs
2 x digital outputs (programmable as 32kHz pulse outputs)
2 x digital output (SPDT Single Pole Double Throw contact type)
2 x digital output (SPDT Single Pole Double Throw contact type)
Analog inputs
2 x analog inputs (0-20mA / 4-20mA / 0-10V DC)
Analog outputs
1 x analog output (0-20mA / 4-20mA)
Degree of protection
IP20
Display
Graphical local control panel (LCP 102)
Current consumption
(525-600Vac; normal duty) 23 A
(525-600Vac; heavy duty) 28 A
(525-600Vac; heavy duty) 28 A
Power dissipation/losses
220 W
300 W
300 W
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 61800-5-2
IEC 61508 SIL2
IEC 62061
ISO 13849-1 PLd
cULus
CE
SEMI F47
EAC
ABS
RINA
BV
LR
ClassNK
DNV
GL
IEC 61508 SIL2
IEC 62061
ISO 13849-1 PLd
cULus
CE
SEMI F47
EAC
ABS
RINA
BV
LR
ClassNK
DNV
GL
Related Documents
Name | Last Update | Language |
---|---|---|
Danfoss - VLT - FC 300 - Selection guide.pdf | 29 Nov 2018 | English (US) |