FLOWLINE
LU84-5101
Ultrasonic liquid level sensor / transmitter - FLOWLINE (EchoSpan LU84) - 30cm...10m / 12inches...32.8feet (ft) sensing range - 2" NPT fluid / process connection - 1 x analog output (4-20mA; 2-wire) - Rated pressure 2bar / 30psi - 1/2" NPT (dual) conduit entry for electrical connection - IP65 / NEMA 4X - Rated for -40...+71°C (ambient) / -20...+60°C (process fluid) - Supply voltage 12Vdc-28Vdc (24Vdc nom.) - Material Polycarbonate (PC) (housing) / Polyvinylidene fluoride (PVDF) (transducer) / Brass / Stainless steel (enclosure hardware) / Viton (gasket) - with LCD display (6-digit) - with P.button configuration
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
LU84-5101
Online Price
$1,580.10 CAD
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
FLOWLINE - EchoSpan LU84LU84-5101
Description
Ultrasonic liquid level sensor / transmitter - FLOWLINE (EchoSpan LU84) - 30cm...10m / 12inches...32.8feet (ft) sensing range - 2" NPT fluid / process connection - 1 x analog output (4-20mA; 2-wire) - Rated pressure 2bar / 30psi - 1/2" NPT (dual) conduit entry for electrical connection - IP65 / NEMA 4X - Rated for -40...+71°C (ambient) / -20...+60°C (process fluid) - Supply voltage 12Vdc-28Vdc (24Vdc nom.) - Material Polycarbonate (PC) (housing) / Polyvinylidene fluoride (PVDF) (transducer) / Brass / Stainless steel (enclosure hardware) / Viton (gasket) - with LCD display (6-digit) - with P.button configuration
Specifications
Primary brand
FLOWLINE
Main function
Sensor (Liquid level)
Product series / family name
EchoSpan LU84
Functions
Ultrasonic liquid level sensor / transmitter
P.button
P.button
Supply voltage (DC)
12Vdc-28Vdc
Sensing distance
30cm...10m
12inches...32.8feet (ft)
12inches...32.8feet (ft)
Number of circuits
2-wire
Pressure
2bar
30psi
30psi
Temperature
-20...+60°C (process fluid)
Connection type
2" NPT fluid / process connection
1/2" NPT (dual) conduit entry
1/2" NPT (dual) conduit entry
Analog outputs
1 x analog output (4-20mA; 2-wire)
Degree of protection
IP65
NEMA 4X
NEMA 4X
Material
Polycarbonate (PC) (housing)
Polyvinylidene fluoride (PVDF) (transducer)
Brass / Stainless steel (enclosure hardware)
Viton (gasket)
Polyvinylidene fluoride (PVDF) (transducer)
Brass / Stainless steel (enclosure hardware)
Viton (gasket)
Ambient air temperature for operation
-40...+71 °C
Display
LCD display (6-digit)
Manufacturer product status
Commercialized
Compliant with standard(s)
CE
RoHS
RoHS
Benefits
Offered in 4 measurement ranges from 9.8’ (3m) to 32.8’ (10m)
Configuration is simple via integral push button display module
LCD display indicates level in inches; centimeters and percentages
Narrow 2” or 3” beam width for applications with limited measurement space
Fail-safe intelligence and diagnostic feedback for simple troubleshooting
PVDF transducer and NEMA 4X polycarbonate enclosure for corrosive liquids
Automatic temperature compensation for accurate measurement
Configuration is simple via integral push button display module
LCD display indicates level in inches; centimeters and percentages
Narrow 2” or 3” beam width for applications with limited measurement space
Fail-safe intelligence and diagnostic feedback for simple troubleshooting
PVDF transducer and NEMA 4X polycarbonate enclosure for corrosive liquids
Automatic temperature compensation for accurate measurement
Resolution
2mm / 0.079in
Application type
bulk storage
day tank
waste sump
day tank
waste sump
Related Documents
Name | Last Update | Language |
---|---|---|
FLOWLINE - EchoSpan LU80 LU81 LU83 LU84 - Datasheet.pdf | 23 Jun 2020 | English (US) |